Very good; i like observations made. would be nice to formulate conclusions and include error analysis. rs

Composition

Pablo Destefanis, Argentina,
Gachari D. Muthoni, Kenya
Ezin C. Eugene, Benin
Lopez Joaquin, Argentina
Faisal Gulzar, Pakistan
Oladipo Olushola Abel, Nigeria
Nkengurukiyimana Damas, Burundi
Ntitsane Thabo, Lesotho


Cables description
Cable A: 2 N connectors, R6-214/U having 50 ohms impedance
Cable B: 2 N connectors
Cable C: 2 N connectors, XT-213 SN having 50 ohms impedance
Cable D: 2 BNC connectors + 2 adaptors BNC to N, R6-58A/U having 50 ohms impedance
Cable E: 2 N connectors
Cable F: 2 BNC connectors + 2 adaptors BNC to N, R6-59 having 75 ohms impedance.

Experiment 1: Testing cable attenuation with Power Meter and Power Sensor


Objective

Use a power meter to measure a reference single produced by a single generator
Characteristics of equipments

The power meter HP 435

The power sensor

Procedure

Following the procedures depicted in Radio Laboratory Handbook, page 39-41, six different cables were measured. Attenuation per meter calculated. The results are given in the following table. Note that cable F has an impedance of 75 ohm, which is not compatible with the devices we used.

2,4GHz @ 1mW

Cable#Attenuation [dB ]Output [mW]Length [m]Attenuation per meter [dB/meter ]
A0.450.911.040.43
B9.50.121.039.22
C17.40.018634.850.50
D23.80.0004419.161.24
E3.50.453.31.06
F3.80.423.90.97


Observations:

The cable B has the highest attenuation per meter. Cable A is of relatively the same length as Cable B and has the lowest attenuation per meter. Cable C presented the most favourable results by giving 0.50dB/meter even though it was 34.85 meters long. Cables E and F produced relatively close levels of attenuation per meter.Cable D registered an attenuation of 1.24dB per meter.

Experiment 2: Power Measurement with Spectrum Analyser

Objective

The purpose of this experiment is to measure the loss of a cable in a continuous range of frequencies by using the previous spectrum analyzer.

Equipment used

The spectrum analyzer R3261/3361 Series Advantest Corporation with its own tracking generator.
Reference cable is with 2N connectors of 1.02 m of length.

Procedure

Following the procedures depicted in Radio Laboratory Handbook, page 43-45, six different cables were measured. The results are given in the following table.

Cable#Attenuation [dB ]Length [m]Attenuation per meter [dB/meter ]
A0.471.040.45
B8.201.037.96
C17.4534.850.5
D24.419.161.27
E3.653.31.10
F3.923.91.01


Observations:

The cable B has the highest attenuation per meter. Cable A is of relatively the same length as Cable B and has the lowest attenuation per meter. Cable C presented the most favourable results by giving 0.50dB/meter even though it was 34.85 meters long. Cables E and F produced relatively close levels of attenuation per meter.Cable D registered an attenuation of 1.27dB per meter.

Experiment 3: Measurement of Cable Loss with Spectrum Analyser and Tracking Generator

Objective

The purpose of this experiment is to use the spectrum analyzer together with a signal generator to measure the loss of a cable in a continuous range of frequencies.

Equipment used

A spectrum analyzer
A tracking generator
An interconnection cable
The cables under measurement.

Procedure

Following the procedures depicted in Radio Laboratory Handbook, page 46-50, six different cables were measured. The results are given in the following table.

Cable#Attenuation [dB ]Length [m]Attenuation per meter [dB/meter ]
A0.211.040.20
B8.91.038.64
C17.334.850.49
D24.019.161.25
E3.93.31.18
F4.13.91.05


Observations:

The cable B has the highest attenuation per meter. Cable A is of relatively the same length as Cable B and has the lowest attenuation per meter. Cable C presented the most favourable results by giving 0.49dB/meter even though it was 34.85 meters long. Cables E and F produced relatively close levels of attenuation per meter.Cable D registered an attenuation of 1.25dB per meter.

CONCLUSION
Considering the observations above, we can say that the cable C presented favourable result.